Tel.: +86 574 6222 6513
Tel.: +86 574 6222 6513
Installation
Hazardous areas Zone 1 (Gas)
Hazardous areas Zone 21 (Dust)
UL
Class I Division 2 Group A, B, C, D
Class II Division 1 Group E, F, G
Class II Division 2 Group F, G
Class III Division 1 & 2
ATEX
II 2G Ex db eb mb IIC T5 Gb (Lens Type)
II 2D Ex mb tb IIIC T5 Db (Lens Type)
II 3G Ex ec mb IIC T5 Gc (Reflective Type)
II 2D Ex mb tb IIIC T5 Db (Reflective Type)
Certificate No SGS25ATEX0003X
IECEx
Ex db eb mb IIC T5 Gb (Lens Type)
Ex mb tb IIIC T5 Db (Lens Type)
Ex ec mb IIC T5 Gc (Reflective Type)
Ex mb tb IIIC T5 Db (Reflective Type)
Certificate No IECEx SGS 25 .0003X
Certificate & Standard
USA: UL1598, UL8750, UL 844
Canada: C22.2#250, CSA C22.2#137
EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-7
EN/IEC 60079-18; EN/IEC 60079-31.
Product Highlight
●SP05 series explosion - proof linear lights from SAFER - Ex, based on its compact and slim design, have an attractive appearance.
The independent LED driver chamber with external airflow heat sink provides excellent heat dissipation.
● Multi-intelligent Technologies such as Microwave Motion Sensor,Photocell Sensor,Dimming,DALI control system are option,
which are among the highest in the industry.
Light efficacy | 148lm/W | 148lm/W | 148lm/W | |||||||||||
Luminous Flux | 7400lm | 8880lm | 11100lm | |||||||||||
Fixture Weight | 6.8kg | 6.8kg | 6.8kg | |||||||||||
Type of Protection | Ex db eb mb (Flameproof, Increased Safety, Encapsulation) Ex tb (Dust Protected Enclosure) | |||||||||||||
ATEX Classification | GroupII Category 2 GD | |||||||||||||
Area Classification | Zone 1 and 21 areas to EN 60079-10-1 and EN 60079-10-2 with installation to EN 60079-14 | |||||||||||||
Certificate | EU Type Examination Certificate SGS25ATEX0006X IECEx Certificate of Conformity IECEx SGS 25 .0003X | |||||||||||||
Coding | Ex db eb mb IIC T6...T5 Gb Ex tb IIIC T80°C...T95°C Db IP66 Refer to table for T rating and Ambient | |||||||||||||
Enclosure | Copper free Die-Casting aluminum with epoxy powder coating finished (RAL 7040) | |||||||||||||
Protective Cover | Tempered Glass / Polycarbonate | |||||||||||||
Entry | 4 cable entries (NPT3/4 ,G3/4,NPT1/2,G1/2,M20,M25 can be selected) | |||||||||||||
Termination | 3 core 6mm² max conductor with looping | |||||||||||||
Control Gear | Electronic Driver | |||||||||||||
Optical Distribution | 60°,90°,140° | |||||||||||||
Colour Temperature (CCT) | 3000K-6000K | |||||||||||||
Colour Rendering Index (Ra) | >80 | |||||||||||||
Maintenance | Back access to gearbox lid with M5 captive screws | |||||||||||||
Impact Protection | IK08 | |||||||||||||
Ingress Protection | IP66 to EN 60529 | |||||||||||||
Surge Protection | 4KV line to line, 6KV line to earth | |||||||||||||
Intelligent Functions | Microwave Motion Sensor, Daylight Sensor, Dimmable, 1Hz Flash, Battery Backup, DALI , LoRa, GPS for option | |||||||||||||
Electrical Supply | 12-24Vac, 100-240Vac 50/60Hz 12-36Vdc, 140-250Vdc | |||||||||||||
Temperature Classification | T5(-40°C+60°C)/T6(-40°C+45°C) | T5(-40°C+60°C)/T6(-40°C+45°C) |
Distribution Curve
Mounting Options
Dimension Diagram
Ordering Information
List of SKU Naming: SP05-75W-MS-E-3K-60-N3/4
Series | Power | Input Voltage | Additional Function | CCT | Beam Angle | Cable Entries | |||||||||||||
SP05 | ‐50 = 50W | - L = 12-24Vac | Empty = No Additional Function | ‐3K = 3000K | ‐60 = 60°(Lens) | -N3/4 = NPT3/4 | |||||||||||||
‐60 = 60W | - E = 100-240Vac | -MS=Microwave Motion Sensor | ‐4K = 4000K | ‐90 = 90°(Lens) | -N3/4=NPT3/4 | ||||||||||||||
‐75 = 75W | - DCL = 12-36Vdc | - DS = Daylight Sensor | ‐5K = 5000K | ‐140 = 140°(Lens) | -G3/4=G3/4 | ||||||||||||||
- DCH = 140-250Vdc | -DM = Dimmable | ‐6K = 6000K | -N1/2=NPT1/2 | ||||||||||||||||
- LR = LoRa | -G1/2=G1/2 | ||||||||||||||||||
- FS = Flash | -M25=M25 | ||||||||||||||||||
- DL = DALI | -M20=M20 | ||||||||||||||||||
- GS = GPS |